November 2018

Conference Paper

A segmented, enriched N-type germanium detector for neutrinoless double beta-decay experiments

By:
Leviner, L.; Aalseth, C.; Radford, David C; Young, A.R.
Journal Name:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Page Number:
66-77
Volume:
735
Issue Number:
N/A
Publication Date:
November 6, 2018
Conference Name:
Low Radioactivity Techniques 2015 (LRT 2015)
Conference Location:
Seattle, Washington, United States of America
Conference Sponsor:
University of Washington
View DOI Listing:
https://doi.org/10.1016/j.nima.2013.08.081

Abstract

We present data characterizing the performance of the first segmented, N-type Ge detector, isotopically enriched to 85% 76Ge. This detector, based on the Ortec PT6×2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the Majorana collaboration. We present some of the general characteristics (including bias potential, efficiency, leakage current, and integral cross-talk) for this detector in its temporary cryostat. We also present an analysis of the resolution of the detector, and demonstrate that for all but two segments there is at least one channel that reaches the Majorana resolution goal below 4 keV FWHM at 2039 keV, and all channels are below 4.5 keV FWHM.


Related Researchers