May 2016

Journal

Evaluating the solid electrolyte interphase formed on silicon electrodes: A comparison of ex situ X-ray photoelectron spectroscopy and in situ neutron reflectometry

By:
Fears, Tyler M; Doucet, Mathieu ; Browning, James F; Baldwin, J; Winiarz, Jeffrey; Kaiser, Helmut; Taub, H.; Sacci, Robert L; Veith, Gabriel M
Journal Name:
Physical Chemistry Chemical Physics
Page Number:
13927-13940
Volume:
18
Issue Number:
20
Publication Date:
May 18, 2016
View DOI Listing:
https://doi.org/10.1039/C6CP00978F

Abstract

This work details the in situ characterization of the interface between a silicon electrode and an electrolyte using a linear fluorinated solvent molecule, 0.1 M lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) in deuterated dimethyl perfluoroglutarate (d6-PF5M2) (1.87 x 10-2 mS/cm). The solid electrolyte interphase (SEI) composition and thickness determined via in situ neutron reflectometry (NR) and ex situ X-ray photoelectron spectroscopy (XPS) were compared. The data show that SEI expansion and contraction (breathing) during electrochemical cycling was observed via both techniques; however, ex situ XPS suggests that the SEI thickness increases during Si lithiation and decreases during delithiation, while in situ NR suggests the opposite. The most likely cause of this discrepancy is the selective removal of SEI components (top 20 nm of the SEI) during the electrode rinse process, required to remove electrolyte residue prior to ex situ analysis, demonstrating the necessity of performing SEI characterizations in situ.