June 2026

Journal

Non-invasive Ultrasonic Sensing of Internal Conditions on a Partial Full-Scale Spent Nuclear Fuel Canister Mock-Up

By:
Zhuang, Bozhou; Gencturk, Bora; Sinkov, Anton; Good, Morris; Meyer, Ryan M; Oberai, Assad
Journal Name:
NDT & E International
Page Number:
103242
Volume:
TBD
Publication Date:
June 18, 2026
View DOI Listing:
https://doi.org/10.1016/j.ndteint.2024.103242

Abstract

The safe storage of spent nuclear fuel (SNF) in dry cask storage systems (DCSSs) is critical to the nuclear fuel cycle and the future of nuclear energy. A crucial component of DCSSs is the SNF canister, which is a sealed stainless structure first vacuum dried and then backfilled with helium. The structural deterioration within a canister can be monitored through its internal gas properties. This monitoring serves as the driving force behind the non-invasive ultrasonic sensing approach in this paper. A major challenge in collecting gas-borne signals is the impedance mismatch between the stainless-steel canister and the helium gas inside. Only a small fraction of the ultrasonic signal makes its way from the transmitter to the receiver through the gas medium. In this paper, experimental studies on a partial full-scale canister mock-up were carried out to capture the gas-borne signals. Damping materials were applied on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The research results showed that the excitation frequency played an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight (TOF) at 225 kHz. A high signal-to-noise ratio (SNR) was achieved in the measurements. Next, acoustic impedance matching (AIM) layers were added, and it was found that the gas signal energy was improved by 160.4% compared with that of no AIM layers. Subsequently, the relative humidity (RH) level and temperature of the gas were varied to simulate abnormal internal conditions of the canister. The non-invasive testing system demonstrated reliability and sensitivity in detecting gas temperature and RH variations. Theoretical calculations demonstrated the potential for detecting low-level xenon and air within an actual SNF canister filled with helium. Last, an active noise cancellation (ANC) method was verified on the canister mock-up for the first time. The results showed that the SNR of the gas signal was improved by 213.6% compared with that of no ANC.


Related Researchers