May 2010

Conference Paper

SNS INJECTION AND EXTRACTION SYSTEMS ? ISSUES AND SOLUTIONS

By:
Plum, Michael A
Publication Date:
May 4, 2010
Conference Name:
ICFA HB 2008
Conference Location:
Nashville, Tennessee, United States of America

Abstract

Beam loss is higher than expected in the Ring injection section and in the injection dump beam line. The primary causes are fairly well understood, and we have made some equipment modifications to reduce the loss. In the ring extraction beam line the beam distribution exhibits cross-plane coupling (tilt), and the cause has been traced to a large skew-quadrupole component in the extraction Lambertson septum magnet. In this paper we will discuss the issues surrounding the ring injection and extraction systems, the solutions we have implemented to date, and our plans for future improvements.