June 2013

Conference Paper

STATUS OF VARIOUS SNS DIAGNOSTIC SYSTEMS

By:
Blokland, Willem ; Purcell, John D; Patton, Jeffrey G; Pelaia Ii, Thomas A; Sundaram, Madhan ; Pennisi, Terry R
Page Number:
2658-2660
Publication Date:
June 20, 2013
Conference Name:
2007 Particle Accelerator Conference
Conference Location:
Albuquerque, New Mexico, United States of America

Abstract

The Spallation Neutron Source (SNS) accelerator systems are ramping up to deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. Enhancements or additions have been made to several instrument systems to support the ramp up in intensity, improve reliability, and/or add functionality. The Beam Current Monitors now support increased rep rates, the Harp system now includes charge density calculations for the target, and a new system has been created to collect data for the beam accounting and present the data over the web and to the operator consoles. The majority of the SNS beam instruments are PC-based and their configuration files are now managed through the Oracle relational database. A new version for the wire scanner software was developed to add features to correlate the scan with beam loss, parking in the beam, and measuring the longitudinal beam current. This software is currently being tested. This paper also includes data from the selected instruments.