February 2010

Journal

The impact of TXV heating on the performance of air-source heat pump in heating mode

By:
Gao, Zhiming
Journal Name:
Energy Conversion and Management
Page Number:
732-739
Volume:
51
Issue Number:
4
Publication Date:
February 1, 2010
View DOI Listing:
https://doi.org/10.1016/j.enconman.2009.10.030

Abstract

The paper discusses the strategy of TXV heating, which adds a limited amount of heat on the surface of TXV sensor, to achieve energy saving and low cost in air-source heat pumps. The TXV heating is able to retard the valve closing so as to boost energy saving in heating mode. The testing results demonstrate the appropriate TXV heating achieves a remarkable improvement in COP and thermal comfort. The required heating power is not more than 40w. The additional equipment cost of TXV heating is less than $20. Thus, the strategy of TXV heating is practical from the view of technology and economy.