April 2010

Journal

Three-dimensional particle trajectories and waste beam losses in injection dump beam line of SNS accumulator ring

By:
Wang, Jian-Guang ; Plum, Michael A
Journal Name:
Physical Review Special Topics - Accelerators and Beams
Page Number:
14002-14002
Volume:
11
Issue Number:
1
Publication Date:
April 26, 2010
View DOI Listing:
https://doi.org/10.1103/PhysRevSTAB.11.014002

Abstract

The SNS ring injection dump beam line has been suffering high beam losses since its commissioning. In order to understand the mechanisms of the beam losses, we have performed 3D simulation studies of the beam line. The 3D models consist of three injection chicane dipoles and one injection dump septum magnet. 3D particle trajectories in the models are computed. We then extend particle optics calculations to the injection dump. Our studies have clearly shown some design and operation problems, that cause beam losses in the injection dump beam line. These include incorrect chicane dipole settings, incorrect position of a chicane dipole, too small aperture of injection dump septum, and inadequate focusing downstream. This paper reports our findings and the remedies to the injection beam loss problems.